Sunvts test reference manual




















Note: The external loopback test is intended for Sun internal manufacturing use only. It requires a custom loopback connector that is not available to an external customer. The user must verify that. To reach the following dialog box, right-click on the test name in the System Map and select Test Parameter Options. If you do not see this test in the System Map, you might need to expand the collapsed groups, or your system might not include the device appropriate to this test.

Enables or disables the external loopback test. This test requires a special loopback plug. This option is available only for IEEE parallel port printer. Enables or disables the printer test; this test requires a printer to be attached to the parallel port. The printer test must be enabled. A postscript printer must be attached to print postscript data. This option is available only for IEEE compatible parallel printer. Selects a delay between passes of the printer test.

This prevents continuous printing of data that could quickly empty the paper supply. This is only meaningful if the printer test is enabled. Sets the print intervals. This option lets you select the intervals at which the test image is printed.

Opens and closes the parallel port device. No data is transferred. The test passes if the device can be opened and closed successfully. The test also passes if the device cannot be opened because the device is busy with another process. Registers a failure if the port is found busy. The unavailability of the device is interpreted as an indication of a fault condition.

On ecpp 7D devices the test runs the internal loopback test and the test can optionally run the external loopback test or the printer test.

Connection test complete. Specifies the name of an ses device in the enclosure. The disk names are separated by colons :. If this option is disabled, the test will access all disks found in the enclosure.

Enables or disables the display of detailed status information regarding the enclosure elements. Enables or disables the Enclosure Services Functional test. Sets the minimum delay in seconds between successive invocations of the test. If a test is not present in this directory, then it may only be available as a bit test. For more information refer to Bit and Bit Tests. All rights reserved. SunVTS 5.

A disk enclosure. A front panel display for configuration information. TABLE enatest Coverage Test Coverage Description Host Connections enatest searches for all the active and inactive connections between the host and the enclosure and reports the number of existing active connections.

This functional test involves the following steps: Perform control operation. Verify control operation was successful. Restore state to what it was before 1. Verify restore operation was successful. The test will fail if any one of the above steps fails.

Enclosure Services Functional test detailed Disk test description Control Operation--Each port of the disk is toggled from its original state. Restore State--Restore the fan speed to the original speed. Description Connection test Yes In this mode, the host connections and the status of the enclosure are checked. Sun StorEdge A5 x 00 Test enatest. Enclosure Services Functional test general description.

Enclosure Services Functional test detailed Disk test description. Functional offline. New OpenBoot commands, configuration variables, and disk drive hot-plug procedures.

Also provides procedures for mapping between logical and physical device names for internal storage devices. Information on how to configure the Sun GigabitEthernet driver software. Describes how to configure the SunATM driver software. Information about how to use Dynamic Reconfiguration software features on these Sun Enterprise servers.

Describes how to configure the Sun Quad FastEthernet driver software. Describes how to configure the Sun GigaSwift Ethernet driver software. Describes how to configure the eri FastEthernet driver software. Describes how to configure the dmfe FastEthernet driver software. Contains configutation information for Dynamic Configuration on the Sun Enterprise system. Contains information about how to use Dynamic Configuration software features on the Sun Fire V system. Sun Enterprise SSP 3.

Contains information about how to use Dynamic Configuration software features on the Sun Enterprise system. Man pages for Sun Enterprise Dynamic Reconfiguration. Installation and release note information for Capacity on Demand on the Sun Enterprise server.

Sun Enterprise Capacity on Demand 1. System administrator information for Capacity on Demand on the Sun Enterprise server. Man pages for Capacity on Demand on the Sun Enterprise server. Overview of software for the Sun Fire 15K system software. System Management Services 1. Installation and release note information for System Management Services 1. System administrator information for System Management Services 1.